Name |
Workbook |
Worksheet |
Cell |
Sim# |
|
Minimum |
Mean |
Maximum |
x1 |
p1 |
x2 |
p2 |
x2-x1 |
p2-p1 |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
1 |
Plans |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
2 |
Site Plan Survey |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
3 |
Permits |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
4 |
Site Work/Tree Removal |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
5 |
Foundation |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
6 |
Plumbing - Slab |
0 |
0.013 |
1 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
7 |
Survey - Foundation |
0 |
0.987 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
8 |
Waterproofing |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
9 |
Grading Backfill |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
10 |
Gravel Basement |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
11 |
Termite Protection |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
12 |
Basement Slab |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
13 |
Framing |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
14 |
Fireplace- Rough |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
15 |
Roofing/Shingles |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
16 |
Plumbing- Rough |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
17 |
HVAC - Rough |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
18 |
Exterior Trim/Siding |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
19 |
Windows & Doors |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
20 |
Steel-Brick |
0 |
0.501 |
1 |
0 |
5% |
1 |
95% |
1 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
21 |
Electrical - Rough |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
22 |
Prime Exterior |
0 |
0.503 |
1 |
0 |
5% |
1 |
95% |
1 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
23 |
Masonry |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
24 |
Security - Rough IN |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
25 |
General Site Cleanup |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
26 |
Insulation - Batts |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
27 |
Septic Tank/Sewer Line |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
28 |
Utility Connections |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
29 |
Brick Clean |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
30 |
Drywall |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
31 |
Water Line |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
32 |
Roofing - Brick Flashing |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
33 |
Shutters |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
34 |
Grading - Final |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
35 |
Driveway |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
36 |
Guttering |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
37 |
Deck |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
38 |
Wrought Iron Railing |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
39 |
Fireplace -Final |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
40 |
Hardwood Flooring - Rough |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
41 |
Cabinets & Vanities |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
42 |
Interior Trim |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
43 |
Cultured Marble Tops |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
44 |
Ceramic Tile |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
45 |
Garage Doors |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
46 |
Painting - Exterior |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
47 |
Painting - Interior |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
48 |
HVAC - Final |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
49 |
Hardware - Interior |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
50 |
Clean - Windows |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
51 |
Plumbing - Final |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
52 |
Appliances |
0 |
0.504 |
1 |
0 |
5% |
1 |
95% |
1 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
53 |
Light Fixtures |
0 |
0.504 |
1 |
0 |
5% |
1 |
95% |
1 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
54 |
Electrical - Final |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
55 |
Security - Final |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
56 |
Insulation - Blown |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
57 |
Landscaping |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
58 |
Survey - Final |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
59 |
Wallpaper |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
60 |
Hardwood Flooring - Final |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
61 |
Mirrors |
0 |
0.503 |
1 |
0 |
5% |
1 |
95% |
1 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
62 |
Shower Enclosures |
0 |
0.499 |
1 |
0 |
5% |
1 |
95% |
1 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
63 |
Flooring - Carpet |
0 |
0.498 |
1 |
0 |
5% |
1 |
95% |
1 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
64 |
Flooring - Vinyl |
0 |
0.507 |
1 |
0 |
5% |
1 |
95% |
1 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
65 |
Trim - Punch Outs |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
66 |
Cleanup - Pre-Final |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
67 |
Paint - Touch Ups |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
68 |
Power Wash Exterior |
0 |
0 |
0 |
0 |
5% |
0 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
69 |
Clean - Final |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
| Output 2 |
Increase in project time? / Event time+ |
House Corrections2.xls |
Model |
M79 |
70 |
Punch List Items |
1 |
1 |
1 |
1 |
5% |
1 |
95% |
0 |
90% |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|